Elastic Networks Appendix B: Cabling Specifications
08-01101-01, Rev. 1.50 BitStorm 1900 Installation and Maintenance Guide B-161
Power Cable Harness
Figure B-14 (shown below) illustrates the BitStorm 1900 cable har-
ness. The BitStorm 1900 power cable assembly connects the DC power
source to the BitStorm Access Multiplexer shelf. One BitStorm 1900
power cable harness contains connectors to support three BitStorm
Access 1900 Multiplexer shelves.
Figure B-14: Power Cable Harness
Power Connector Terminations
The end of the BitStorm 1900 power cable assembly that connects to
the power source has two red and two black leads. Each lead is termi-
nated with 24-4 ring clips. If using a DC power supply, the BitStorm
1900 power cable assembly must terminate at the DC power source as
shown in Table B-5. Refer to the WARNING label on the next page.
Red and Black
Ring Clip Leads (4)
Mate-N-Lok
Connector (4-prong)
Table B-5: Terminal Connection for DC Power Source
Power Cable
Connector
Power Source Terminal Connection
Red (2) DC supply Negative (-)
Black (2) DC return Positive (+)